Scope and the Rule Behind It

NFPA 211 expects a flue liner that is continuous, sized to the appliance it serves and able to take that appliance's heat. Cracked clay tile, a missing liner, or an insert venting into an oversized flue all fail that test. We size a stainless liner to the stove, insert or furnace, add insulation when the framing sits too close, and connect it at both ends. Lynwood owners get camera images of the old and new flue.

Liner size matched to the appliance
Insulation added when framing sits too close
Tee or adapter joint at the base
Top plate and cap on the crown
Camera images of the old and new flue

When the Standard Calls for a Liner

A flue lining has two jobs. It shields the masonry, and the joists and studs nearest it, from the heat and acids in exhaust, and it gives the smoke a passage of the right size so it rises and leaves. NFPA 211 expects every chimney to have one, intact and suited to the appliance it serves. Older chimneys in Lynwood usually have clay tile, which works well until it cracks. A chimney fire, a strong quake, or years of water coming through a bad crown can split tiles or open the joints between them, and once that happens the lining has a hole. A Level 2 inspection with video is how most of these get found, and the report will tell you whether the damage is a few joints or a broken flue. A broken flue cannot be fixed from the top with mortar. It is relined, or the chimney is rebuilt, and relining is usually the smaller job.

The other common reason is a change of appliance. A gas or wood insert, a wood stove or a pellet stove each comes with a manual that sets the liner it needs, and most call for a full-length stainless liner of a stated size. Furnace changes cause a quieter problem. Many homes vented a gas furnace and a water heater through one masonry flue. When the old furnace is replaced with a high-efficiency model that vents out the side of the house, the water heater is left alone in a flue far too big for it. Its exhaust cools before reaching the top, condenses in the chimney and can spill back into the house. That is an orphaned water heater, and the fix is a liner sized for it. We see it often in older houses across Los Angeles.

How a Liner Is Sized, Fitted and Priced

A liner is a listed part, tested as a system with its fittings, and the listing sets how it is installed. Size comes from the appliance: its manual or the venting tables for gas appliances give the diameter, and a liner too large is nearly as poor as one too small. Some installs need an insulating wrap or poured insulation around the liner, either because the listing calls for it to meet clearances or because the chimney is an outside wall where exhaust would cool too fast. At the bottom the liner connects to the appliance or a tee; at the top it is fixed to a plate that closes off the old flue, with a cap over the outlet. On an open wood fireplace, relining is possible but more involved, since the liner must be sized to the fireplace opening and properly sealed to the smoke chamber. We will explain which applies to yours.

The written quote states the liner type and diameter, its length, any wrap or fill around it, how it meets the appliance, how the old flue is closed off up top, any change to the damper or smoke chamber needed to let it pass, and a permit if the city requires one for the work. Price varies with the chimney height, the diameter, the insulation and how easy the roof is to work on, so each job is priced in writing after we have measured. If the chimney also needs crown or masonry repair, those come first, because a liner inside a leaking chimney still sits in water. Once installed, the system gets the video check so you have a record of the new flue. Homeowners in Lynwood, South Gate, Inglewood and across Los Angeles can start through the contact page. Mention what the chimney serves and any recent appliance change.

How Malloy Chimney Group Handles the Paperwork

Rule Cited

Each finding names the NFPA 211 or code point it touches

Photo Record

Pictures of the fault and the finished work in the report

Signed Quote First

Work outside the booked job waits for your signature

Permit Noted

The quote says whether the city wants a permit

Where we offer chimney liner installation

This service is booked from the main page above in every covered city; the areas index lists them all.

All covered cities

Nothing on file under that name. Check the spelling or try the ZIP code instead.

Related Services

Chimney Sweep

Creosote brushed off the flue walls and bagged, with a written note on how heavy the deposit was and what NFPA 211 asks next.

Rule and scope →

Chimney Inspection

An NFPA 211 Level 1 check of the reachable chimney, written up with photos and a verdict on whether it is fit to use.

Rule and scope →

Chimney Repair

Repairs sorted into code items and upkeep items, so you can see which ones an inspector would flag.

Rule and scope →

Fireplace Inspection

The room side of the system measured against code: hearth extension, trim clearances, firebox walls, damper and doors.

Rule and scope →

Fireplace Repair

Firebox, damper, doors and hearth put right, with any short hearth or close trim brought back within code distances.

Rule and scope →

Chimney Level 2 Inspection

The deeper NFPA 211 inspection with a camera down the whole flue, required by the standard at a sale or after damage.

Rule and scope →

Chimney Cap Installation

Spark arrester mesh in the size the residential code sets, on a stainless cap fitted to one flue or the full crown.

Rule and scope →

Chimney Flashing Repair

Step and counter flashing reset where the roof meets brick, with crickets added where the code calls for one.

Rule and scope →

Chimney Masonry Repair

Open joints repointed and flaking brick swapped out, using a mortar no stronger than the brick it sits between.

Rule and scope →

Chimney Rebuilds

Unsound stacks taken down and laid up again to current height, clearance and reinforcement rules, under a permit where the city wants one.

Rule and scope →

Fireplace Cleaning

Firebox, grate, smoke shelf and glass doors cleaned from the room side, for fireplaces that burn a few nights a year.

Rule and scope →

Gas Fireplace Cleaning

Burner, pilot, log set and glass cleaned on a gas unit, with the vent end and the gas fittings checked under the maker's manual.

Rule and scope →

Gas Fireplace Repair

Meter testing traces a failing pilot, igniter, valve or control board, and the repair uses the replacement parts named in the unit's listing.

Rule and scope →

Fireplace Remodel

New facings, mantels and hearths planned around the clearances the residential code sets for trim and hearth size.

Rule and scope →

Fireplace Inserts

Gas and wood inserts set to the maker's listing, connected to a full liner, with permit and clearance checks in the quote.

Rule and scope →

Pellet Stove Repair

Feed motors, igniters, fans and safety sensors on pellet stoves tested and replaced with listed parts, then the vent run inspected.

Rule and scope →

Wood Stove Repair

Door seals, baffles, firebrick and glass on wood stoves renewed, plus the wall and floor clearances checked against the stove's label.

Rule and scope →

Gas Logs

Gas log sets matched to the firebox and the limits in their listing, with the gas connection and valve fitted to code.

Rule and scope →

Chimney Seismic Retrofit

Brick stacks braced, strapped or rebuilt lighter above the roof, scoped after we check the mortar and how the stack meets the house.

Rule and scope →

Chimney Crown Repair

Cracked or flat crowns sealed or recast so water runs off the top, with a gap kept so the flue tile can move.

Rule and scope →

Dryer Vent Cleaning

Lint cleared from the dryer duct and the outside hood, with the run length and duct material checked against the mechanical code.

Rule and scope →

Chimney Leak Repair

Water traced to the exact place it gets in, then fixed at that place, with photos showing the path.

Rule and scope →

Chimney Waterproofing

Siloxane repellent that sheds rain yet lets vapor out, used as the last step once repairs have closed the gaps.

Rule and scope →

Chimney Damper Repair

Throat dampers that stick, rust or leak air repaired or replaced, with a top-mounted damper as the other option.

Rule and scope →

Chimney Chase Cover

Rusting tops on framed chimneys replaced with a stainless cover cut to the chase, shaped so water runs off and away.

Rule and scope →
Call (323) 524-7126